Our Products
- Distribution Transformers
- Power Transformer
- Auto Recloser Circuit Breaker
- MV Overhead Switch with Break under SF6
- Air-Insulated Modular Cell
- Fused Compact RMU Cubicle
- Withdrawable Cell
- Aluminum Alloy Conductor
- Medium Voltage Cable, Low Voltage Cable
- Aerial Twisted Cable
- Junction And End Boxes
- Angled And Straight Separable Connector
- Public Lighting
- Manually Operated Aerial Switch
- Generator
- Onduleur
- MV Mobile Transformer Station
- Prefabricated Metal Transformer Substation
- HTA Mobile Transformer Station
- MV/LV Transformer Substation
- Voltage Regulator
- Rectifier
- Low Voltage Panel
Air-Insulated Modular Cell
Modular cubicles are medium voltage switching devices up to 36 kV intended for indoor use such as in concrete transformer substations, secondary distribution systems and industrial installations.
All the cells needed for an interruption center can be easily installed according to demand.
Being products tested in the factory, their installation and electrifications are very easy to carry out.
Sectioning and breaking operations are carried out under SF6 gas. The busbar is air insulated. Thus the dimensions of the cells decrease while security increases.

HMH series modular cubicles have 4 compartments separated from each other by metal plates:
- Cable and switch compartment
- Busbar compartment
- Operating Mechanism Compartment
- LV compartment
CABLE AND SWITCH COMPARTMENT
The cables are connected to the connection terminal located under the earthing switch. This compartment contains either the load-break switch or the circuit breaker and the earthing switch. Fuse and fuse holders will be added in fuse protection cells.
The switch is in the epoxy resin tank and remains completely separated from the busbar compartment and the cable connection compartment with a sheet metal separation.
BUSBAR COMPARTMENT
The busbar compartment ensures the transmission of energy between the panels using 3 bars. Access to the busbar compartment is via the top of the cubicle.
OPERATING MECHANISM COMPARTMENT
This compartment contains the operating mechanisms of the switches, circuit breakers and earthing switches. Optionally, motorization and additional locks can be added.
LOW VOLTAGE COMPARTMENT
The LV compartment is equipped with different types of protection, control and measurement devices according to customer requirements. The control and observation devices are located at an easily accessible height for the operators. Connections of the BT cables for the auxiliary power supply and the interlocks are easy to make thanks to the adapted design.


Designation | 12kV Voltage | 24kV Voltage | 36kV Voltage |
Rated voltage | 12kV | 24kV | 36kV |
Power frequency withstand voltage (1 min) | 28kV | 50kV | 70kV |
With breaking interval (between contacts in open position) | 32kV | 60kV | 80kV |
Rated lightning impulse withstand voltage (1 min) | 75kV | 125kV | 170kV |
With breaking interval (between contacts in open position) | 85kV | 145kV | 195kV |
Rated frequency | 50-60Hz | 50-60Hz | 50-60Hz |
Rated current | 630-1250 A | 630-1250 A | 630-1250 A |
Rated peak withstand current | 50kA | 40kA | 40kA |
Rated short-time withstand current (1 sec) | 20kA | 20kA | 16-20kA |
Rated active load breaking current | 630A | 630A | 630A |
Rated closed-circuit breaking current | 630A | 630A | 630A |
Rated cable breaking current without load | 16A | 16A | 50A |
Rated line breaking current without load | 2A | 1,5A | 2A |
Rated earth fault current | 10A | 10A | 150A |
Cable and line breaking current on earth fault | 10A | 10A | 87A |
Rated transfer current | 630A | 630A | 630A |
Rated short-circuit making current | 50 kA-Crête | 40 kA-Crête | 40 kA-Crête |
Class | M1-E3 | M1-E3 | M1-E3 |
IP degree of protection | IP2XC | IP2XC | IP2XC |

Others products
Low Voltage Panel
Rectifier (Battery Charger)