Our Products
- Distribution Transformers
- Power Transformer
- Auto Recloser Circuit Breaker
- MV Overhead Switch with Break under SF6
- Air-Insulated Modular Cell
- Fused Compact RMU Cubicle
- Withdrawable Cell
- Aluminum Alloy Conductor
- Medium Voltage Cable, Low Voltage Cable
- Aerial Twisted Cable
- Junction And End Boxes
- Angled And Straight Separable Connector
- Public Lighting
- Manually Operated Aerial Switch
- Generator
- Onduleur
- MV Mobile Transformer Station
- Prefabricated Metal Transformer Substation
- HTA Mobile Transformer Station
- MV/LV Transformer Substation
- Voltage Regulator
- Rectifier
- Low Voltage Panel
Low Voltage Panel

TIPI boards are complete distribution boards.
They are equipped as standard with all the functionalities necessary for the operator to work de-energized and energized in complete safety.
The TIPI switchboard is intended to equip urban public distribution substations.
Use
4 models available:
- TIPI 4-500 HR (4+1 departures)
- TIPI 8-1200 and TIPI 8-1200 HR (8+1 departures)
- TIPI 8-1800 (8+1 departures) for height reduced to 1.5 m/ground
Technical Specifications
HN 63-S-61 (2003)
- IEC 439.1 / IEC 947-3 IEC 269-2
Advantages
- Security and safety of operation, full compliance with international standard IEC 439.1:
- Degree of protection IP2X on all sides of the products,
- Internal insulating separations in accordance with form 4b corresponding to the highest level of safety of the standard (see diagram opposite),
- Switchboard individually tested in 3 routine tests: overall inspection, dielectric test and control of the electrical continuity of the circuits (supply of the test certificate and compliance with the IEC 439.1 standard on request),
- Certified products (approval no. 03E119).
Basic equipment
The tables consist of:
A four-pole general cut-off switch with certain cut-off,
A padlockable short-circuiting and earthing device (upstream of the switch),
A set of 4 IP2X protected bus bars, which can accommodate up to 5 outgoing units
(4+1 provisional) for the TIPI 4-500 A and up to 9 outlets (8+1 provisional) for the TIPI 8-1200 and 8-1800 A, integrated base.
Auxiliary functions:
– Starting unit for supplying a public lighting network,
– 220 V socket,
– Earthing terminal block (MALT) of neutral,
– Protection by circuit breaker of all the auxiliaries which can be
powered by the switchboard (measuring unit or monitoring device, PLC box, fault detector or ITI box).
The starting unit (standard HN 63-S-61)
TIPI starting units are interchangeable and can be mounted on all types of TIPI boards.
TIPI 4-500 HR (dimensions in mm)
Four-pole outgoing units with neutral disconnectable by size 2 strap.
Installation and removal can be done with the busbar
under pressure.
Connection of outgoing units with mechanically tightened cable clamps (without lugs).
Grounding in short circuit and grounding by specialized device
General characteristics | TIPI 4-500HR | TIPI 8-1200 | TIPI 8-1200 HR | TIPI 8-1200 | UD TIPI |
Operating voltage | 400 V | 400 V | 400 V | 400 V | 400 V |
Rated current | 500 A | 1200 A | 1200 A | 1800 A | 500 A |
Overall height with UD in mm | 1400 | 1846 | 1205 | 1846 | 995 |
Overall width in mm | 745 | 1000 | 1446 | 1000 | 100 |
Designation | Nom. | References |
TIPI 4-500 A | 69.82.150 | 0610.200 |
TIPI 8-1200 A | 69.82.156 | 0610.220 |
TIPI 8-1800 A | 69.82.158 | 0610.230 |
IP2X TIPI starting unit (connection with connectors) | 69.82.200 | 0611.100 |
Temporary outgoing 400 A – without fuse | 69.82.202 | 0611.110 |
8D fixing | 69.82.250 | 0961.175 |
8D fixing | 69.82.252 | 0961.176 |
Insulated TORX key for starter fixing | 69.82.820 | 0902.017 |
Silvered copper strip – 400A – center distance 115 mm | 69.43.450 | 0900.760 |
Fuse Size 2 HPC – 125 A – 115 mm | 69.43.007 | 0900.751 |
Fuse Size 2 HPC – 160 A – 115 mm | – | 0900.752 |
Fuse Size 2 HPC – 200 A – 115 mm | 69.43.009 | 0900.753 |



LV switchboards offer ideal fuse protection for LV networks of public distribution.
Efficient, reliable and easy to use, they provide total protection for people, property and the environment in the event of overcurrent.
Range of equipment intended for the protection of rural LV networks supplied by pole-top transformers from 50 to 160 kVA.
Description
- Outdoor-type Low Voltage Switchboard, placed downstream of a conventional pole-top MV/LV transformer with or without MV fused protection.
- Complete range of IP2X switchboards covering powers up to 160 kVA and meeting all needs (1 or 2 feeders, connection of underground lines, supply for a public lighting network, dedicated overload protection for the transformer) .
- 2 versions of fiberglass reinforced polyester casings:
– Traffix SP: basic equipment for an aerial departure (or 2 departures on the same protection).
– Traffix DP: possibility of starting underground and supplying a public lighting network.
Advantages
- Protection optimale des départs de réseau par fusible à Haut Pouvoir de Coupure.
- Simplicité et fiabilité de la protection ; efficacité absolue sur court-circuit.
- Protection ne vieillissant pas et ne nécessitant pas de maintenance.
- Associé à un transformateur TPC Cahors, c’est l’assurance d’une coordination idéale du schéma de protection entre la MT et la BT.
- Mise en place rapide.
- Protection mécanique des câbles jusqu’à 2 m. du sol.
- Indice de protection IP2X facilitant les travaux sous tension.
- Fermeture du coffret par vis plombables et condamnation possible avec un cadenas.
Technical Specifications
- HN 63-S-12 / HN 63-S-62: Protection devices for rural LV networks.
- IEC 60269-1 and IEC 60269-2: Low Voltage Fuse Circuit Breaker.
- IEC 439.1-2 and IEC 947.3: Power switchgear assembly.
Others products
Rectifier (Battery Charger)
Voltage Regulator
MV/LV Transformer Substation
