MV Overhead Switch with Break under SF6 (Auto Sectionaliser)
SF6 cut-off switches are equipment designed for outdoor installation on medium voltage overhead lines.
- Standards
The manufacture of the equipment is carried out following a quality management program in accordance with the international standard ISO 9001. Likewise, the development and manufacture of the Devices are carried out in accordance with the following standards:
- IEC 62271-1 (IEC 60694): High voltage equipment. Part 1: Common characteristics.
- IEC 62271-102 (IEC 60129): High voltage equipment. Part 102: AC disconnectors and earthing switches.
- IEC 62271-103 (IEC 60265-1): High voltage switches. Part 1: High voltage switches for rated voltages above 1 kV and below 52 kV.
- IEC 62271-200 (IEC 60298): Metal-enclosed switchgear for alternating voltages greater than 1 kV and less than or equal to 52 kV.

Table of electrical characteristics
RATED VOLTAGE | Ur | kV |
| 24 |
| 36 |
ASSIGNED FREQUENCY | Fr | Hz |
| 50 |
| 50 |
INSULATION LEVEL |
|
| TO THE EARTH | DISTANCE DE DE SECC. |
| DISTANCE DE DE SECC. |
Lightning impulse withstand voltage 1.2/50 µs | Up | kVpk | 125 | 145 | 170 | 185 |
Industrial frequency 50 Hz 1 min | Ud | kV | 50 | 60 | 70 | 80 |
RATED CURRENT | Ir | A | 400/630 | 400 |
Admissible short-time current 1 s. | Ik | kA | 12/05/16 | 12,5 / 16 |
Permissible peak current | Ip | kApk | 31,5 / 40 | 31,5 / 40 |
Short-circuit duration | tk | s | A | A |
Fundamentally active charging current | 1 charge | A | 400/630 | 400 |
Courant nominal de coupure en boucle fermée | 1 boucle | A | 400/630 | 400 |
No-load cable rated breaking current | Icc | A | 16 | 16 |
No-load line rated breaking current | I1C | A | 1,5 | 1,5 |
Rated earth fault breaking current | Ief1 | A | 50 | 50 |
Rated cable or line breaking current in the event of an earth fault | Ief2 | A | 16 | 16 |
Rated short-circuit breaking current (5 makings) | Ima | kA | 31,5/40 | 31,5/40 |
Allowable temperature | T | ºC | -25 / + 50 | -25 / + 50 |
CLASS ACCORDING TO IEC 62271-103 STANDARD |
|
| M1E3 * | M1E3 * |
CREEPAGE | LF | mm | (III) – 780 (IV) – 1055 | 1055 |
1- TYPES OF ASSEMBLY

2- DIMENSIONS

The Overhead Switch-Disconnector has the following functions: • Operation at rated load; • Closing in short circuit; • Effective isolation according to standard IEC 62271-102.
The device consists of the following components:
- Switch with mounting bracket for support on the Pole;
- Manual control with actuation tube located at the base;
- Surge protectors (optional);
- Voltage transformers (optional);
• Union and transfer tubes.

SF6 switch disconnectors are designed to be integrated correctly into the natural environment: compact, equipped with a protection system against volatiles, etc.
The cut-off and control device as well as the connections are located inside the metal cube is enveloped in an atmosphere filled with SF6 gas; Thus the devices are protected against adverse weather and environmental conditions, such as corrosion, wind, industrial pollution, etc. It also facilitates maintenance since only the wiring with the medium voltage line, the position indicator and the control lever are located outside the device.
In addition, the production of Overhead Switches follows a process and uses materials that ensure minimal leakage rate (sealed for life).
The Overhead Switch opening and closing mechanism includes:
- A self-extinguishing insulating chamber
It consists of a rotating copper moving contact and two fixed contacts for each phase (copper coated with silver to provide electrical conductivity). The cut occurs at two points simultaneously.
- Actuation mechanism
The actuation of the switch is carried out by a single spring mechanism, which performs the maneuver independently of the speed of the operator. The spring loads and unloads by turning the lever in either direction. The mechanism has two positions (open or closed).

Operation
The spring, mentioned above, is actuated by a rotating shaft attached to the switch. The maneuver can be carried out by:
- Insulated pole (not included),
- Rotary transmission lever and tube;
- IA74 type swing control
The operating mechanism and the open-closed position indicators are housed inside a painted stainless steel frame sealed with a gasket.

An indicator linked to the movements of the switch contacts ensures the indication of its position: open or closed. The latter is thus perfectly visible from the support base where the device is located.
MV Connexions
The switch-disconnector can be equipped with:

Anchoring
The device includes a support piece for the tower on which it is installed.
This support piece is a universal type for all types of post (concrete, metal, or wood)

Vertical mounting: manual control at the base
The equipment is operated locally from the support base where it is installed by the rotary tube and lever.
The system includes a manually operated button at the base of the tower operated by a lever with the possibility of mechanical locking by a padlock. The equipment and the control are physically connected by a 1” tube.
The control base has two positions:
- OPEN and locked
- CLOSED and locked
Horizontal installation: manual control by pole
The disconnect device (not included) is operated locally from the support base through an isolated pole. Both positions can be locked.
Horizontal Installation: Manual Override by Overhead Switch Control
Equipment in the horizontal position is operated locally from the base through an IA74 type control. This manually operated control is physically connected to the device via a 1″ tube.
As an option, it is possible to include a surge arrester directly mounted on the equipment.
This equipment does not require any additional operations, it is pre-assembled at the factory to ensure correct operation. All three or six surge protectors are mounted on a support which is fixed directly to the equipment.